- Contact Person : Ms. Wu Ella
- Company Name : A & E Technology Import & Export Co., Ltd.
- Tel : 86-20-28039790
- Fax : 86-20-28039794
- Address : Guangdong,Guangzhou City,#1811, 18F, No.55 Xi Di Er Rd.
- Country/Region : China
- Zip : 510000
Atomic Absorption Spectrometer
A & E Lab.
Main Products: Atomic Absorption Spectrometer (AAS), Fluorescence Spectrophotometer, Bio-Spectrophotometer, UV Vis Spectrophotometer, Visible Spectrophotometer, Flame Photometer, Whiteness Meter, Turbidity Meter, Colorimeter, Gloss Meter, Tintometer, Automatic Polarimeter, Auto Melting Point Apparatus, Automatic Refractometer, Abbe Refractometer, PH/DDS/TDS Meter, etc.
Features:
Fully Automated
² The flame and graphite furnace is integrated into one instruments.The change over from one technique to
another is carried out by simple key strokes within the software.
² The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and
optimization of each hollow cathode lamp by the software.
² The spectral bandwidth is automated and is available with choice of five slit sizes.
Advanced Graphite Furnace
² Horizontally heated platform graphite tube.The unique design of graphite furnace reduces the chemical
interference effects and memory effects by uniformly heating the graphite electrode.
² The computer controlled heating program all.Iows the users to select the best heating program for analysis.
² The optical temperature during the atomization stage ensures the rapid heating and rapid analysis.This helps
to extend the life of graphite tube and enhance the analytical accuracy.
Flame Analysis
Sensitivity(Cu): 2.0μg/ml Absorption>0.2 Abs
Detection(Cu): Cu<0.0004μg/ml(flame);Cd<0.4×10-12g(graphite furnace)
Cu<0.7%(Air-Acetylene Analysis);
Ba<1% (Nitrous Oxide Analysis)
Cu<2%,Cd<2%(Graphite Furnace Analysis)
Background Correction: Deuterium Lamp>×40,Self Reversal>×60
Character Concentration:
<0.02μg/ml1%(Cu);<0.15mg/ml1%(Nitrous Oxide-Acetylene,Ba)
Character Value: Cu<0.3×10-10g,Cd<0.3×10-12g
Burner Head: Titanium Alloy Burner
Nebulizer: High-Efficiency Glass Nebulizer
Atomization Chamber: Corrosion-Resistant Material
Position Adjustment: Automatic Changeover of Flame and Furnace
Automatic setting of Optimum Height for Flame Burner
Safety Functions: Burner identification,Flame Sensor,Gas leak sensor,
Low gas pressure sensor,power loss protection,gas loss flame protection
Model | AE-AA500 |
Optic System | |
Wavelength Range | 190nm-900nm |
Monochromator | Czemy-Turner Configuration |
Spectral Bandwidth | 0.1nm,02nm,0.4nm,1.0nm, 2.0nm (5steps,Automatic Changeover) |
Wavelength Accuracy | ±0.15nm |
Wavelength Repeatability | <0.05nm |
Resolution | <30% or 0.2nm ±0.02nm |
Baseline Stability | 0.005A/30min |
Atomic Absorption Spectrometer