Atomic Absorption Spectrometer (AA990)
A & E Lab.
Main Products: Atomic Absorption Spectrometer (AAS), Fluorescence Spectrophotometer, Bio-Spectrophotometer, UV Vis Spectrophotometer, Visible Spectrophotometer, Flame Photometer, Whiteness Meter, Turbidity Meter, Colorimeter, Gloss Meter, Tintometer, Automatic Polarimeter, Auto Melting Point Apparatus, Automatic Refractometer, Abbe Refractometer, PH/DDS/TDS Meter, etc.
Features:
Fully Automated
² The flame and graphite furnace is integrated into one instrument.The change over from one technique to another
is carried out by simple key strokes within the software.
² The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and
optimisation of each hollow cathode lamp by the software.
² The control of the gas flows for the fuel gas (C2H2 ) and the positioning of the bumer is also carried out directly
from the software thus allowing optimization of the instruments for the best analytical parameter for a selected
analysis.
² Two methods of background correction are available.The first utilises a deuterium lamp and the second is the
proven method of self reversal.
² The location of the wavelength and peak selection is automatic and controlled from the software. The spectral
bandwidth is automated and is available with a choice of five slit sizes.
² The electronic parameters for the photomultiplier detector,the hollow cathode lamp current and the balancing of
the absorbance and background energies are controlled from the software.
² The igntion of the flame is computer controlled and the various safety interlocks offer a very safe operating system.
Technical Specifications:
Flame analysis
Sensitivity(Cu): 0.03μg/ml/1%
Burner Head: Titanium alloy burner
Atomization Chamber: Corrosion-resistant material
Position Adjustment: Automatic Changeover of Flame and Furnace
Automatic setting of Optimum Height for Flame Burner
Safety: Automatic ignition and mixing air-acetylene gas with safety control.
Graphite furnace analysis
Character Value(Cd): 0.5Pg
Temperature Range: Ambient-2650°C
Heating: Voltage feedback control when dry and ashing;
Optical temperature control when atomizing.
Heating program: Up to 9 steps with choices of ramp,temperature increase and full-power heating
Background Correction:
Deuterium Lamp Background Correction: 1.0Abs self-Reversal Background Correction: 3.0Abs
Date processing
Analytical method: flame,graphite furnace and hydride.
Model | AE-AA990 |
Optic System | |
Wavelength Range | 190nm-900nm |
Monochromator | Czemy-Turner Configuration |
Spectral Bandwidth | 0.1nm,0.2nm,0.4nm,1.0nm,2.0nm(5steps. with automatic change over) |
Wavelength Accuracy | ±0.25nm |
Wavelength Repeatability | 0.15nm |
Baseline Stability | 0.005A/30min |